PF Active Circuit Connections

This page describes how the MAST-U poloidal field coils are electrically connected to their power supply circuits.

Overview

The PF active system consists of 13 power supplies driving 25 coils through various circuit topologies (series, parallel, and anti-series configurations).

MAST-U Supplies and Coils

Power Supplies:

supplies = [
    'D1PS', 'D2PS', 'D3PS', 'DPPS', 'D5PS', 'D6PS', 'D7PS',
    'P1PS', 'EFPS', 'PXPS', 'SFPS', 'MFPS', 'RFPS'
]

Coils:

coils = [
    'D1U', 'D1L', 'D2U', 'D2L', 'D3U', 'D3L', 'DPU', 'DPL',
    'D5U', 'D5L', 'D6U', 'D6L', 'D7U', 'D7L', 'P1', 'PC',
    'PXU', 'PXL', 'P4U', 'P4L', 'P5U', 'P5L', 'P6U', 'P6L'
]

Supply Coil Geometry Circuit Notes
D1PS D1U d1_upper Series
D1L d1_lower
D2PS D2U d2_upper Series
D2L d2_lower
D3PS D3U d3_upper Series
D3L d3_lower
DPPS DPU dp_upper Series
DPL dp_lower
D5PS D5U d5_upper Series
D5L d5_lower
D6PS D6U d6_upper Series
D6L d6_lower
D7PS D7U d7_upper Series
D7L d7_lower
P1PS P1 p1_inner Parallel 1 coil for current but two geometrically, central solenoid
p1_outer
EFPS PC pc Parallel Not currently in use
- - - -
PXPS PXU px_upper Series
PXL px_lower
SFPS P4U p4_upper Series
P4L p4_lower
MFPS P5U p5_upper Series
P5L p5_lower
RFPS P6U p6_upper Anti-Series
P6L p6_lower

Circuit Topologies

Series Circuit

In a series circuit, coils are connected end-to-end. The same current flows through all coils in the circuit.

Series Circuit Diagram

S1(1) S1(2) C1(1) C1(2) C2(1) C2(2)
1 1 0 1 0 0 0
2 0 1 0 0 0 1
3 0 0 0 1 1 0

Parallel Circuit

In a parallel circuit, coils share the same voltage. The current is divided between the parallel branches.

Parallel Circuit Diagram

S1(1) S1(2) C1(1) C1(2) C2(1) C2(2)
1 1 0 1 0 1 0
2 0 1 0 1 0 1

Anti-Series Circuit

In an anti-series circuit, coils are connected with opposite polarity. This configuration is used for coils that need to operate with reversed magnetic field direction.

Anti-Series Circuit Diagram

S1(1) S1(2) C1(1) C1(2) C2(1) C2(2)
1 1 0 0 1 0 0
2 0 1 0 0 0 1
3 0 0 1 0 1 0

Connection Matrices

The complete IMAS connection matrix encodes the electrical topology of all circuits:

  • 13 circuits = 13 connection matrices (one per power supply)
  • 13 power supplies driving the system
  • 25 coils in total across all circuits
  • All coils and supplies appear in the matrix in the order defined in the IDS
  • Approximately ~76 columns in the full connection matrix

Data Representation

The connection matrices are generated using the pf_conn_matrix custom function, which creates the appropriate circuit topology matrix for each power supply based on its configuration.

Each matrix row represents a circuit node, and columns represent: - Supply connections (S columns) - Coil connections (C columns)

Matrix values indicate electrical connectivity between nodes.

Special Cases

EFPS and PC (Central Coil):

  • The EFPS circuit and PC coil are not currently operational
  • Connection matrix expected to be parallel topology but contains all zeroes (as of 26/10/23)
  • These are maintained in the IDS structure for potential future use

Full Connection Matrix Visualization

Full IMAS Connection Matrix

Data Sources

Circuit connection data is generated from:

  • Signal: Power supply name (e.g., D1PS, P1PS)
  • Function: pf_conn_matrix - Custom MAST-U function that generates the connection topology
  • Source: CUSTOM_MASTU data source