Ensure that the Central Solenoid [OH] coil current / copper area < Maximum value author: G Turkington, CCFE, Culham Science Centre args : output structure : residual error; constraint value; residual error in physical units; output string; units string #=# physics #=#=# f_copperaoh_m2, copperaoh_m2_max and hence also optional here. Logic change during pre-factoring: err, symbol, units will be assigned only if present. copperaoh_m2 : input real : CS coil current at EOF / copper area [A/m2] copperaoh_m2_max : input real : maximum coil current / copper area [A/m2] f_copperaoh_m2 : input real : f-value for CS coil current / copper area
Type | Intent | Optional | Attributes | Name | ||
---|---|---|---|---|---|---|
real(kind=dp), | intent(out) | :: | tmp_cc | |||
real(kind=dp), | intent(out) | :: | tmp_con | |||
real(kind=dp), | intent(out) | :: | tmp_err | |||
character(len=1), | intent(out) | :: | tmp_symbol | |||
character(len=10), | intent(out) | :: | tmp_units |
subroutine constraint_eqn_089(tmp_cc, tmp_con, tmp_err, tmp_symbol, tmp_units)
!! Ensure that the Central Solenoid [OH] coil current / copper area < Maximum value
!! author: G Turkington, CCFE, Culham Science Centre
!! args : output structure : residual error; constraint value;
!! residual error in physical units; output string; units string
!! #=# physics
!! #=#=# f_copperaoh_m2, copperaoh_m2_max
!! and hence also optional here.
!! Logic change during pre-factoring: err, symbol, units will be assigned only if present.
!! copperaoh_m2 : input real : CS coil current at EOF / copper area [A/m2]
!! copperaoh_m2_max : input real : maximum coil current / copper area [A/m2]
!! f_copperaoh_m2 : input real : f-value for CS coil current / copper area
use rebco_variables, only: copperaoh_m2, copperaoh_m2_max, f_copperaoh_m2
implicit none
real(dp), intent(out) :: tmp_cc
real(dp), intent(out) :: tmp_con
real(dp), intent(out) :: tmp_err
character(len=1), intent(out) :: tmp_symbol
character(len=10), intent(out) :: tmp_units
tmp_cc = 1.0d0 - f_copperaoh_m2 * copperaoh_m2_max / copperaoh_m2
tmp_con = copperaoh_m2
tmp_err = copperaoh_m2 * tmp_cc
tmp_symbol = '<'
tmp_units = 'A/m2'
end subroutine constraint_eqn_089