ECRH User Input Gamma Model
iefrf/iefrffix
= 10
This model allows the user to input a scaling factor to the current drive efficiency with the variable gamma_ecrh
. The value of this variable should follow the value and form of the expression below:
\gamma_{CD} = \frac{\langle n_{e,20} \rangle I_{CD}R_0}{P_{CD}}
The current drive efficiency is then calculated with \gamma_{CD} in the form below:
\text{Current drive efficiency [A/W]} = \frac{\gamma_{CD}}{R_{0} n_{e,20}}